Research Article | | Peer-Reviewed

Comparative Evaluation of Oxidative Quality and Thermal Oxidative Stability of Commercial Olive Oil Brands Using Lipid Oxidation Indices

Received: 14 September 2026     Accepted: 22 September 2026     Published: 19 November 2026
Views:       Downloads:
Abstract

Olive oil is valued for its nutritional composition and bioactive constituents, but lipid oxidation during storage and heating can reduce quality and produce primary and secondary oxidation products. This study evaluated the oxidative quality and thermal oxidative stability of eleven commercially available extra virgin olive oil brands marketed in Enugu State, Nigeria. Fresh samples (S1–S11) were analysed for peroxide value (PV), p-anisidine value (P-AV), and total oxidation (TOTOX) value. Separate aliquots were heated at 180°C for 10, 15, and 20 min, and all determinations were performed in triplicate. PV was determined by the AOCS iodometric method, P-AV by the AOCS p-anisidine method, and TOTOX was calculated as 2PV + P-AV. Fresh PV, P-AV, and TOTOX values ranged from 4.50 ± 0.95 to 25.85 ± 0.05 meq O2/kg, 0.43 ± 0.05 to 17.50 ± 0.89, and 13.26 ± 1.59 to 53.92 ± 0.55, respectively. After 20 min of heating, PV, P-AV, and TOTOX ranged from 2.25 ± 0.45 to 16.05 ± 0.05 meq O2/kg, 1.64 ± 0.29 to 48.66 ± 6.22, and 16.24 ± 0.13 to 61.36 ± 7.21, respectively. Heating altered the oxidation indices (p < 0.05), but the magnitude and direction of change varied among brands. Some samples showed declining PV during prolonged heating while P-AV or TOTOX remained elevated, demonstrating the dynamic formation and decomposition of oxidation products. The findings show substantial variation in the initial oxidative status and thermal response of commercial olive oils and indicate that PV, P-AV, and TOTOX should be interpreted together when assessing oxidative quality and thermal stability.

Published in International Journal of Nutrition and Food Sciences (Volume 15, Issue 6)
DOI 10.11648/j.ijnfs.20261506.13
Page(s) 332-338
Creative Commons

This is an Open Access article, distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution and reproduction in any medium or format, provided the original work is properly cited.

Copyright

Copyright © The Author(s), 2026. Published by Science Publishing Group

Keywords

Olive Oil, Oxidative Stability, Thermal Oxidation, Peroxide Value, P-anisidine Value, TOTOX, Lipid Oxidation

1. Introduction
Olive oil is highly valued for its nutritional composition, sensory characteristics and bioactive constituents. Its relatively high monounsaturated fatty-acid content, together with phenolic compounds, tocopherols, carotenoids, phytosterols and squalene, contributes to its nutritional value and oxidative behaviour .
Despite these properties, olive oil is susceptible to oxidation during processing, storage, transportation and heating. Lipid oxidation proceeds through the formation of primary products such as hydroperoxides and their subsequent decomposition into secondary products including aldehydes and ketones. These reactions can adversely affect flavour, aroma, nutritional quality and shelf life .
Thermal treatment accelerates oxidation by increasing reaction rates, promoting hydroperoxide decomposition and reducing the effectiveness of endogenous antioxidants. The extent of deterioration depends on fatty-acid composition, phenolic content, processing history, packaging, oxygen exposure, light and storage conditions .
Peroxide value (PV) measures primary oxidation products, whereas p-anisidine value (P-AV) provides information about secondary aldehydic products. Total oxidation (TOTOX), calculated as 2PV + P-AV, integrates both indices and therefore provides a broader description of oxidative status . Because these indices can change in different directions during heating, their combined interpretation is important when assessing thermally treated oils.
Commercial olive oils may differ substantially in oxidative status because products can originate from different cultivars, production systems, storage histories and distribution chains. Comparative testing of products available in Nigerian markets can therefore provide useful evidence for quality monitoring . The present study evaluated eleven commercially available extra virgin olive oil brands using PV, P-AV and TOTOX before and after heating at 180°C for 10, 15 and 20 min.
2. Materials and Methods
2.1. Materials and Sample Collection
Eleven commercially available extra virgin olive oil brands were purchased from retail outlets in Enugu State, Nigeria. Samples were obtained in their original sealed containers, transported to the laboratory under ambient conditions and stored at approximately 25°C in a cool, dry environment protected from direct sunlight. Eleven brands were selected to provide a comparative set of distinct commercial products accessible at the time of sampling.
Table 1. Commercial olive oil samples and codes.

Sample Code

Commercial Olive Oil Brand

S1

Bertolli Extra Virgin Olive Oil

S2

Filippo Berio Extra Virgin Olive Oil

S3

Borges Extra Virgin Olive Oil

S4

Goya Extra Virgin Olive Oil

S5

Gallo Extra Virgin Olive Oil

S6

La Española Extra Virgin Olive Oil

S7

Laser Extra Virgin Olive Oil

S8

Sabroso Extra Virgin Olive Oil

S9

SPAR Extra Virgin Olive Oil

S10

Marc Joseph Extra Virgin Olive Oil

S11

Betis Extra Virgin Olive Oil

2.2. Study Design and Thermal Treatment
A completely randomized design (CRD) was used. Fresh samples S1–S11 were analysed for PV, P-AV and TOTOX. Separate aliquots of each sample were heated in clean glass beakers on a thermostatically controlled hot plate at 180°C for 10, 15 and 20 min and cooled to ambient temperature before analysis. All determinations were performed in triplicate (n = 3).
2.3. Chemicals and Analytical Methods
Analytical-grade reagents were used throughout. Glacial acetic acid, chloroform, potassium iodide, sodium thiosulfate, starch indicator, p-anisidine reagent, iso-octane and distilled water were used for the oxidation analyses.
Peroxide value was determined using the American Oil Chemists' Society (AOCS) iodometric procedure (Cd 8b-90) . Briefly, 1 g of oil was diluted with the acetic acid–chloroform solvent, treated with potassium iodide, diluted with distilled water and titrated against sodium thiosulfate using starch as indicator. The peroxide value was calculated according to the analytical equation used in the study.
P-anisidine value was determined according to the AOCS procedure . Oil samples were dissolved in iso-octane and absorbance was measured at 350 nm before and after reaction with p-anisidine reagent. The method estimates secondary aldehydic oxidation products.
TOTOX was calculated as: TOTOX = (2 × PV) + P-AV. This index integrates information from primary and secondary oxidation products.
2.4. Oxidation Calculations
Percentage change in PV, P-AV and TOTOX after 20 min of heating was calculated as [(final value − initial value) / initial value] × 100. The calculation was used to compare the magnitude of change among S1–S11.
2.5. Statistical Analysis
Data were expressed as mean ± standard deviation (SD) and analysed using SPSS version 16. One-way analysis of variance (ANOVA) was used to test differences among samples. Values of p < 0.05 were considered statistically significant.
3. Results
3.1. Oxidative State of Fresh Olive Oil Samples
Table 2 presents the oxidative indices of fresh samples S1–S11. PV ranged from 4.50 ± 0.95 meq O2/kg (S8) to 25.85 ± 0.05 meq O2/kg (S6). P-AV ranged from 0.43 ± 0.05 (S9) to 17.50 ± 0.89 (S7), while TOTOX ranged from 13.26 ± 1.59 (S1) to 53.92 ± 0.55 (S6). These results indicate substantial differences in initial oxidative status among the commercial brands.
Table 2. Oxidative indices of fresh olive oil samples.

Samples

Peroxide value (meq)

P-anisidine value

Total oxidation value

S1

5.85±0.87a

1.56±0.76bc

13.26±1.59a

S2

6.55±0.93a

12.93±0.72f

26.03±1.18b

S3

10.45±1.45a

14.63±0.49g

35.53±2.41c

S4

21.33±2.57d

9.29±0.23a

51.96±5.33de

S5

6.55±0.87a

3.95±0.71d

17.05±1.71a

S6

25.85±0.05e

2.22±0.65c

53.92±0.55e

S7

16.92±1.49c

17.50±0.89i

51.33±3.30de

S8

4.50±0.95a

13.47±0.60f

22.46±2.39b

S9

23.45±2.05d

0.43 ±0.05a

47.33±4.14d

S10

16.07±0.40c

1.11±0.09ab

33.24±0.72c

S11

10.07±1.13b

16.37±0.76h

36.51±1.59a

Results are expressed as mean ± SD (n = 3). Different superscript letters indicate significant differences at p < 0.05.
3.2. Effect of Heat on Peroxide Value
Table 3 shows the effect of heating at 180°C on PV for S1–S11. After 10 min, PV ranged from 1.85 ± 0.05 meq O2/kg (S1) to 20.15 ± 1.03 meq O2/kg (S11); after 15 min, from 2.65 ± 0.15 (S2) to 15.17 ± 0.58 (S11); and after 20 min, from 2.25 ± 0.45 (S2) to 16.05 ± 0.05 (S6). Percentage change after 20 min ranged from 5% (S11) to 71% (S10).
Table 3. Effect of heat on peroxide value of olive oil samples.

Samples

PV (meq/kg) at 10 min

PV (meq/kg) at 15 min

PV (meq/kg) at 20 min

% change in PV (meq/kg) at 20 min

S1

1.85±0.05a

6.30±0.80c

7.65±0.87cd

24%

S2

6.20±0.90b

2.65±0.15a

2.25±0.45a

66%

S3

6.20±1.20de

12.10±0.20f

12.67±1.42fg

21%

S4

11.95 ± 0.55de

13.32±11.40ef

8.87±1.63d

58%

S5

15.94± 0.55a

4.10±0.20b

3.63±0.65a

45%

S6

16.89±1.14e

13.53±1.33g

16.05±0.05h

39%

S7

8.50±0.40c

11.15±0.55ef

11.15±0.55de

34%

S8

15.27±0.59d

8.23±0.31d

13.38±1.18g

66%

S9

7.92±0.53c

10.52±1.11e

7.05±0.05c

70%

S10

7.75±0.650c

11.08±1.51ef

4.65±0.35b

71%

S11

20.15±1.03f

15.17±0.58h

10.65±0.30e

5%

Results are expressed as mean ± SD (n = 3). Different superscript letters indicate significant differences at p < 0.05.
3.3. Effect of Heat on P-anisidine Value
Table 4 shows the effect of heating on P-AV for S1–S11. After 10 min, values ranged from 0.43 ± 0.05 (S8) to 22.63 ± 1.56 (S10); after 15 min, from 1.11 ± 0.09 (S8) to 20.95 ± 0.69 (S1); and after 20 min, from 1.64 ± 0.29 (S11) to 48.66 ± 6.22 (S5). Percentage change after 20 min ranged from 6% (S4) to 98% (S9).
Table 4. Effect of heat on p-anisidine value of olive oil samples.

Samples

PAV at 10 min

PAV at 15 min

PAV at 20 min

% change in PAV at 20 min

S1

12.77±3.045de

20.95± 0.69fg

16.33±1.56bcd

90%

S2

14.63±0.49de

9.29±0.23def

11.73±1.03b

9%

S3

6.65±0.49e

9.29±0.23def

17.99±0.86cd

19%

S4

17.38±1.44e

15.13±0.89def

14.65±0.50cd

6%

S5

4.35±0.69b

4.46±0.33ab

48.66±6.22g

92%

S6

1.11±3.43d

19.90±10.19g

29.24±7.23f

92%

S7

1.10±0.62a

10.14±0.69bcd

21.59±3.4de

19%

S8

0.43 ±0.05c

1.11±0.09a

16.37±0.76a

18%

S9

13.31±1.23de

20.73±0.89fg

23.55±0.34cde

98%

S10

22.63±1.56e

12.51± 2.31cde

25.25±4.13ef

96%

S11

11.92±0.09de

8.49±0.34bc

1.64±.29a

90%

Results are expressed as mean ± SD (n = 3). Different superscript letters indicate significant differences at p < 0.05.
3.4. Effect of Heat on TOTOX Value
Table 5 shows the effect of heating on TOTOX for S1–S11. After 10 min, values ranged from 9.29 ± 0.52 (S5) to 52.22 ± 2.06 (S11); after 15 min, from 12.66 ± 0.63 (S5) to 53.82 ± 5.31 (S6); and after 20 min, from 16.24 ± 0.13 (S2) to 61.36 ± 7.21 (S6). Percentage change after 20 min ranged from 4% (S10) to 70% (S5).
Table 5. Effect of heat on TOTOX value of olive oil samples.

Samples

Totox at 10 min

Totox at 15min

Totox at 20 min

% change in at 20 min

S1

16.45±2.94b

33.55±0.91c

31.63±2.40c

58%

S2

27.17±1.15b

21.34±0.19b

16.24±0.13a

38%

S3

49.05±3.74f

41.23±0.31e

43.32±2.05d

18%

S4

49.27±1.55f

35.69±7.62c

32.38±2.76c

38%

S5

9.29±0.52a

12.66±0.63a

55.92±6.36e

70%

S6

44.88±1.61d

53.82±5.31g

61.36±7.21e

12%

S7

18.10±0.18b

32.44±1.79c

43.9±4.33d

14%

S8

37.64±1.04d

18.12±0.93a

29.45±2.83c

24%

S9

29.14±2.12c

44.58±1.91f

34.83±0.96c

26%

S10

37.83±2.85d

34.81±5.23cd

34.55±3.44c

4%

S11

52.22±2.06f

38.83±1.36cd

22.94±0.51b

38%

Results are expressed as mean ± SD (n = 3). Different superscript letters indicate significant differences at p < 0.05.
4. Discussion
4.1. Oxidative Quality of Fresh Olive Oil Samples
The fresh samples showed marked differences in PV, P-AV and TOTOX. PV, an indicator of primary lipid oxidation, was lowest in S8 and highest in S6. S4, S6 and S9 exceeded the 20 meq O2/kg maximum specified for extra virgin olive oil by the International Olive Council and Codex standards . This observation indicates that some products had a relatively high primary oxidation burden at the time of analysis. However, the study did not independently determine storage duration, cultivar, antioxidant concentration or supply-chain conditions for individual brands; therefore, these factors should be considered possible explanations rather than demonstrated causes.
P-AV also varied widely. S7 had the highest fresh P-AV, whereas S9 had the lowest. The combination of relatively high PV and low P-AV in S9 contrasts with the relatively moderate PV and high P-AV observed in S7. Such differences are consistent with the dynamic nature of lipid oxidation: hydroperoxides can accumulate initially and later decompose into aldehydic products. Consequently, PV alone may not adequately represent the overall oxidative condition of an oil .
TOTOX integrated the two oxidation indices and showed a broad range among S1–S11. The variation indicates that the brands entered the experiment with different oxidative histories. Packaging, light exposure, oxygen availability, storage temperature, processing history and antioxidant composition are recognised factors affecting olive-oil stability . These variables were not directly measured in the present study and therefore cannot be assigned as specific causes for individual samples.
4.2. Effect of Heat on Peroxide Value
Heating produced different PV trajectories among S1–S11. Some samples showed increases, whereas others declined after prolonged heating. This behaviour is expected because heating can simultaneously accelerate hydroperoxide formation and hydroperoxide decomposition. A declining PV during heating therefore does not necessarily mean that oxidation has decreased; it may indicate that primary oxidation products are being converted into secondary products .
The largest percentage change after 20 min occurred in S10, while S11 showed the smallest percentage change. S1 increased from 1.85 meq O2/kg at 10 min to 7.65 meq O2/kg at 20 min, whereas S2 declined from 6.20 to 2.25 meq O2/kg. These contrasting patterns show why PV should be interpreted together with P-AV and TOTOX when assessing heated oils. The present data demonstrate different responses to the same temperature and heating duration, but the mechanisms responsible for each brand cannot be confirmed without measurements of fatty-acid composition and antioxidants.
4.3. Effect of Heat on P-anisidine Value
Heating markedly changed P-AV in several samples, particularly S5, S6, S9 and S10. At 20 min, S5 recorded the highest P-AV, followed by S6 and S10, indicating substantial accumulation of secondary aldehydic oxidation products. S9 showed the largest percentage change. In contrast, S4 changed relatively little over the same period. The different responses indicate that the initial composition and oxidative history of each product influenced its behaviour during thermal treatment.
The decline observed in S11 from 11.92 at 10 min to 1.64 at 20 min should not be interpreted as evidence of improved oil quality. Secondary oxidation products can themselves undergo further reactions, volatilisation or degradation during prolonged heating . Thus, a lower P-AV after heating can coexist with continued oxidative deterioration. The combined results reinforce the need to evaluate secondary oxidation alongside PV.
4.4. Effect of Heat on TOTOX Value
TOTOX integrates PV and P-AV and therefore captures changes occurring across primary and secondary oxidation. At 20 min, S6 had the highest TOTOX value, followed by S5 and S7, whereas S2 had the lowest. S5 showed the largest percentage increase, while S10 showed the smallest percentage change. The divergent trajectories reflect the fact that oxidation products are continuously formed, transformed and degraded during heating .
The results also demonstrate why no single oxidation index should be interpreted in isolation. Samples with declining PV may still show increasing P-AV or TOTOX, indicating progression from primary to secondary oxidation. Conversely, reductions in TOTOX can occur when measurable oxidation products undergo further degradation. The present study therefore supports the use of PV, P-AV and TOTOX together when comparing thermal oxidative behaviour of commercial olive oils.
5. Conclusion
Eleven commercial extra virgin olive oil brands showed substantial differences in oxidative status before heating and in their responses to heating at 180°C. PV, P-AV and TOTOX changed differently among S1–S11, demonstrating that thermal oxidation is dynamic and that a single oxidation index cannot fully describe oil deterioration. The combined assessment of primary and secondary oxidation indices provides a broader basis for evaluating the oxidative quality and thermal behaviour of commercial olive oils.
6. Recommendations
Routine quality assessment of commercial olive oils should include PV, P-AV and TOTOX rather than relying on a single index. Storage and distribution should minimise exposure to heat, light and oxygen. Regulatory and quality-control laboratories may use comparative oxidation testing to monitor products marketed as extra virgin olive oil. Further studies should measure fatty-acid composition, total phenolic compounds, tocopherols and other antioxidants, and should investigate repeated heating cycles and storage conditions to explain differences among brands.
Abbreviations

AOCS

American Oil Chemists' Society

ANOVA

Analysis of Variance

CRD

Completely Randomized Design

P-AV

p-anisidine Value

PV

Peroxide Value

SD

Standard Deviation

TOTOX

Total Oxidation

Author Contributions
Simcha Chinyere Okeyahweh: Conceptualization, Data curation, Formal Analysis, Funding acquisition, Investigation, Methodology, Writing – original draft
Lazarus Afamefuna Okoye: Conceptualization, Formal Analysis, Supervision, Validation, Writing – review & editing
Patrick Okechukwu Ugwudike: Supervision, Validation, Writing – review & editing
Conflicts of Interest
The authors declare no conflicts of interest.
References
[1] American Oil Chemists' Society. (1998). Official method Cd 8b-90: Peroxide value, acetic acid–isooctane method. In Official methods and recommended practices of the American Oil Chemists' Society. AOCS Press.
[2] American Oil Chemists' Society. (2024). Official methods and recommended practices of the AOCS (7th ed.). AOCS Press.
[3] Boskou, D., Tsimidou, M. Z., & Blekas, G. (2021). Olive oil: Chemistry and technology (3rd ed.). AOCS Press.
[4] Choe, E., & Min, D. B. (2007). Chemistry of deep-fat frying oils. Journal of Food Science, 72(5), R77–R86.
[5] Frankel, E. N. (2014). Lipid oxidation (2nd ed.). Woodhead Publishing.
[6] Gagour, J., El Gharby, S., Harhar, H., Kartah, B., & Charrouf, Z. (2024). Recent advances in assessing the oxidative stability and quality of virgin olive oil during storage and thermal processing. Foods, 13, 1125.
[7] Gharby, S., Harhar, H., Kartah, B., El Monfalouti, H., & Charrouf, Z. (2023). Factors affecting the quality and oxidative stability of virgin olive oil: A review. Foods, 12(3), 512.
[8] Gündüz, G. T., & Baştürk, A. (2023). Assessment of peroxide value, p-anisidine value and oxidative quality of commercially available edible oils marketed in Türkiye. Food Control, 152, 109865.
[9] International Olive Council. (2023). Trade standard applying to olive oils and olive-pomace oils (COI/T.15/NC No. 3/Rev. 19). International Olive Council.
[10] International Organization for Standardization. (2017). ISO 3960: 2017. Animal and vegetable fats and oils—Determination of peroxide value—Iodometric (visual) endpoint determination. International Organization for Standardization.
[11] Lozano-Castellón, J., López-Yerena, A., Rinaldi de Alvarenga, J. F., Vallverdú-Queralt, A., & Lamuela-Raventós, R. M. (2023). Phenolic compounds in extra virgin olive oil: Composition, stability, and health effects. Antioxidants, 12(9), 1776.
[12] Ma, X., Wang, Y., Li, H., Zhang, Y., Liu, Z., & Chen, Q. (2023). Advances in lipid oxidation mechanisms and oxidative stability assessment of edible vegetable oils. Food Chemistry, 405, 134814.
[13] Matos, C., Sanches Silva, A., & Peres, A. M. (2022). Thermal degradation and oxidative stability of edible oils: Current analytical approaches and quality indicators. Foods, 11(23), 3816.
[14] Mehany, T., El-Sayed, S. M., Hassan, A., & Abdel-Aziz, M. (2025). Effect of thermal processing on the oxidative stability and antioxidant properties of edible oils: A comprehensive review. Food Reviews International. Advance online publication.
[15] Shahidi, F., & Zhong, Y. (2020). Lipid oxidation and improving the oxidative stability. Chemical Society Reviews, 49(4), 1145–1190.
[16] Stefanidis, S., Kalogeropoulos, N., & Andrikopoulos, N. K. (2023). Oxidative stability, phenolic composition, and quality characteristics of extra virgin olive oil during storage and thermal treatment. Antioxidants, 12(8), 1548.
[17] Tarapoulouzi, M., Kalogeropoulos, N., Chiou, A., & Andrikopoulos, N. K. (2022). Evaluation of peroxide value, p-anisidine value and TOTOX index for assessing the oxidative deterioration of edible oils during thermal processing. Foods, 11(19), 3024.
[18] Codex Alimentarius Commission. (2023). Standard for Olive Oils and Olive Pomace Oils (CXS 33-1981). Food and Agriculture Organization of the United Nations (FAO)/World Health Organization (WHO).
Cite This Article
  • APA Style

    Okeyahweh, S. C., Okoye, L. A., Ugwudike, P. O. (2026). Comparative Evaluation of Oxidative Quality and Thermal Oxidative Stability of Commercial Olive Oil Brands Using Lipid Oxidation Indices. International Journal of Nutrition and Food Sciences, 15(6), 332-338. https://doi.org/10.11648/j.ijnfs.20261506.13

    Copy | Download

    ACS Style

    Okeyahweh, S. C.; Okoye, L. A.; Ugwudike, P. O. Comparative Evaluation of Oxidative Quality and Thermal Oxidative Stability of Commercial Olive Oil Brands Using Lipid Oxidation Indices. Int. J. Nutr. Food Sci. 2026, 15(6), 332-338. doi: 10.11648/j.ijnfs.20261506.13

    Copy | Download

    AMA Style

    Okeyahweh SC, Okoye LA, Ugwudike PO. Comparative Evaluation of Oxidative Quality and Thermal Oxidative Stability of Commercial Olive Oil Brands Using Lipid Oxidation Indices. Int J Nutr Food Sci. 2026;15(6):332-338. doi: 10.11648/j.ijnfs.20261506.13

    Copy | Download

  • @article{10.11648/j.ijnfs.20261506.13,
      author = {Simcha Chinyere Okeyahweh and Lazarus Afamefuna Okoye and Patrick Okechukwu Ugwudike},
      title = {Comparative Evaluation of Oxidative Quality and Thermal Oxidative Stability of Commercial Olive Oil Brands Using Lipid Oxidation Indices},
      journal = {International Journal of Nutrition and Food Sciences},
      volume = {15},
      number = {6},
      pages = {332-338},
      doi = {10.11648/j.ijnfs.20261506.13},
      url = {https://doi.org/10.11648/j.ijnfs.20261506.13},
      eprint = {https://article.sciencepublishinggroup.com/pdf/10.11648.j.ijnfs.20261506.13},
      abstract = {Olive oil is valued for its nutritional composition and bioactive constituents, but lipid oxidation during storage and heating can reduce quality and produce primary and secondary oxidation products. This study evaluated the oxidative quality and thermal oxidative stability of eleven commercially available extra virgin olive oil brands marketed in Enugu State, Nigeria. Fresh samples (S1–S11) were analysed for peroxide value (PV), p-anisidine value (P-AV), and total oxidation (TOTOX) value. Separate aliquots were heated at 180°C for 10, 15, and 20 min, and all determinations were performed in triplicate. PV was determined by the AOCS iodometric method, P-AV by the AOCS p-anisidine method, and TOTOX was calculated as 2PV + P-AV. Fresh PV, P-AV, and TOTOX values ranged from 4.50 ± 0.95 to 25.85 ± 0.05 meq O2/kg, 0.43 ± 0.05 to 17.50 ± 0.89, and 13.26 ± 1.59 to 53.92 ± 0.55, respectively. After 20 min of heating, PV, P-AV, and TOTOX ranged from 2.25 ± 0.45 to 16.05 ± 0.05 meq O2/kg, 1.64 ± 0.29 to 48.66 ± 6.22, and 16.24 ± 0.13 to 61.36 ± 7.21, respectively. Heating altered the oxidation indices (p < 0.05), but the magnitude and direction of change varied among brands. Some samples showed declining PV during prolonged heating while P-AV or TOTOX remained elevated, demonstrating the dynamic formation and decomposition of oxidation products. The findings show substantial variation in the initial oxidative status and thermal response of commercial olive oils and indicate that PV, P-AV, and TOTOX should be interpreted together when assessing oxidative quality and thermal stability.},
     year = {2026}
    }
    

    Copy | Download

  • TY  - JOUR
    T1  - Comparative Evaluation of Oxidative Quality and Thermal Oxidative Stability of Commercial Olive Oil Brands Using Lipid Oxidation Indices
    AU  - Simcha Chinyere Okeyahweh
    AU  - Lazarus Afamefuna Okoye
    AU  - Patrick Okechukwu Ugwudike
    Y1  - 2026/11/19
    PY  - 2026
    N1  - https://doi.org/10.11648/j.ijnfs.20261506.13
    DO  - 10.11648/j.ijnfs.20261506.13
    T2  - International Journal of Nutrition and Food Sciences
    JF  - International Journal of Nutrition and Food Sciences
    JO  - International Journal of Nutrition and Food Sciences
    SP  - 332
    EP  - 338
    PB  - Science Publishing Group
    SN  - 2327-2716
    UR  - https://doi.org/10.11648/j.ijnfs.20261506.13
    AB  - Olive oil is valued for its nutritional composition and bioactive constituents, but lipid oxidation during storage and heating can reduce quality and produce primary and secondary oxidation products. This study evaluated the oxidative quality and thermal oxidative stability of eleven commercially available extra virgin olive oil brands marketed in Enugu State, Nigeria. Fresh samples (S1–S11) were analysed for peroxide value (PV), p-anisidine value (P-AV), and total oxidation (TOTOX) value. Separate aliquots were heated at 180°C for 10, 15, and 20 min, and all determinations were performed in triplicate. PV was determined by the AOCS iodometric method, P-AV by the AOCS p-anisidine method, and TOTOX was calculated as 2PV + P-AV. Fresh PV, P-AV, and TOTOX values ranged from 4.50 ± 0.95 to 25.85 ± 0.05 meq O2/kg, 0.43 ± 0.05 to 17.50 ± 0.89, and 13.26 ± 1.59 to 53.92 ± 0.55, respectively. After 20 min of heating, PV, P-AV, and TOTOX ranged from 2.25 ± 0.45 to 16.05 ± 0.05 meq O2/kg, 1.64 ± 0.29 to 48.66 ± 6.22, and 16.24 ± 0.13 to 61.36 ± 7.21, respectively. Heating altered the oxidation indices (p < 0.05), but the magnitude and direction of change varied among brands. Some samples showed declining PV during prolonged heating while P-AV or TOTOX remained elevated, demonstrating the dynamic formation and decomposition of oxidation products. The findings show substantial variation in the initial oxidative status and thermal response of commercial olive oils and indicate that PV, P-AV, and TOTOX should be interpreted together when assessing oxidative quality and thermal stability.
    VL  - 15
    IS  - 6
    ER  - 

    Copy | Download

Author Information
  • Abstract
  • Keywords
  • Document Sections

    1. 1. Introduction
    2. 2. Materials and Methods
    3. 3. Results
    4. 4. Discussion
    5. 5. Conclusion
    6. 6. Recommendations
    Show Full Outline
  • Abbreviations
  • Author Contributions
  • Conflicts of Interest
  • References
  • Cite This Article
  • Author Information