| Peer-Reviewed

Sanitary Status and Bio-monitoring of Surface Water Quality in the City of Maroua (Far North, Cameroon)

Received: 5 May 2022    Accepted: 1 June 2022    Published: 9 June 2022
Views:       Downloads:
Abstract

A study to assess the physico-chemical and microbiological quality of surface water was conducted from September 2019 to September 2020 in the town of Maroua. With the objective of evaluating the physico-chemical and microbiological quality of the surface water of this town. The sampling stations were chosen on 3 main watercourses in each district of the town. Sampling was done on a fortnightly basis for one year. The results were grouped by seasons. The physico-chemical analyzes consisted of measuring the following parameters: temperature, pH, electrical conductivity, turbidity, chloride, sodium and sulphate content. The biological analyzes of the water focused on the search for bacteria, yeasts and microscopic fungi. The spatiotemporal variations of the physico-chemical parameters revealed water with relatively high temperatures during the two seasons. Suspended solids are generally higher in water during the rainy season (45, 227, 321 and 427 mg/l respectively at M4, M1, M5 and M3) reflecting on high turbidity over 2800 NTU during both seasons at M2 station in Kaliao mayo. The microbiology of water has shown three groups of microorganisms like bacteria, yeasts and fungi. From the microorganisms isolated, the majority were bacteria 84%, yeasts 8% and fungi 8%. The most represented germs in surface water’s samples in Maroua are by medical interest importance: Salmonella spp., Vibrio spp., Legionella spp., then Campylobacter spp. and Aeromonas spp.. Alongside, Mycobacterium species, Candida spp., Cryptococcus spp. and Trichophyton spp. were scarce. These results testify to the occurrence of pathogenic germs in surface water in the city of Maroua. Hence the resurgence of epidemic diseases such as Cholera.

Published in American Journal of Biomedical and Life Sciences (Volume 10, Issue 3)
DOI 10.11648/j.ajbls.20221003.13
Page(s) 70-80
Creative Commons

This is an Open Access article, distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution and reproduction in any medium or format, provided the original work is properly cited.

Copyright

Copyright © The Author(s), 2024. Published by Science Publishing Group

Keywords

Bio-monitoring, Physico-Chemistry, Microbiological Quality, Surface Water, Maroua

References
[1] WHO. (2010). Chapter 11: Microbial fact sheets. In: Guidelines for drinking-water quality. 3rd edition. World Health Organization, Geneva, Switzerland.
[2] PNDP. (2011). National Participatory Development Program.
[3] AWWA. (2006). AWWA manual of water supply practices – M48 Waterborne pathogens. 2nd edition. American Water Works Association, Denver, Colorado.
[4] Shigomnou Daniel. (2004). Analysis and redefinition of the climatic and hydraulic regimes of Cameroon: Prospects for the evolution of water resources.
[5] Sigha Nkamdjou et al. (1998). Variability of the hydrological regimes of the rivers of the southern strip of the South Cameroon plateau. AHS Pubi, 1–8.
[6] Moussima Yaka, DA, Tiemeni, AA, Zing, BZ, Jokam Nenkam, TLL, Aboubakar, A., Nzeket, AB, Fokouong Tcholong, BH, & Mfopou Mewouo, YC (2020). Physico-chemical and bacteriological quality of groundwater and health risks in some districts of Yaoundé VII, Cameroon. International Journal of Biological and Chemical Sciences, 14 (5), 1902–1920. https://doi.org/10.4314/ijbcs.v14i5.32.
[7] APHA. (1998). Standard method for examination of water and wastewater, American Public Health Association, 20th edition, Washington, DC, 1150 p.
[8] APHA. (2005). AMERICAN PUBLIC HEALTH ASSOCIATION (APHA), AMERICAN WATER WORKS ASSOCIATION (AWWA), WATER ENVIRONMENT FEDERATION (WEF), Standard Methods for the Examination of Water and Wastewater; 21st edition,, 5220D.
[9] ANGELIER, E. (2000). Running water ecology. Tech & Doc. ed. Paris, 199 p.
[10] Ward JH 1963. Hierarchical grouping to optimize an objective function. Journal of American Statistical Association, 58: 236 p.
[11] StatSoft France (2005). STATISTICA (data analysis software), version 7.1.
[12] Ter Braak CJF, Smilauer P., 2002. CANOCO Reference Manual and CanoDraw for Window user's guide: Software for Canonical Community Ordination (Version 4.5). Micro-computer Power, Ithaca, New York, USA, 351 p.
[13] Hammer, Øyvind, Harper, David A. T., and Paul D. Ryan, 2001. Past: Paleontological Statistics Software Package for Education and Data Analysis. Palaeontologia Electronica, vol. 4, issue 1, art. 4: 9pp., 178kb. http://palaeo-electronica.org/2001_1/past/issue1_01.htm. 9 p.
[14] WHO. (2004). Drinking-water quality guidelines, hygiene criteria and supporting documentation Vol. 2. World Health Organization 2nd edition, 1050p.
[15] WHO (2017). Quality guidelines for drinking water: 4th ed. incorporating the first addendum [Guidelines for drinking-water quality: 4th ed. incorporating first addendum] ISBN: 978-92-4-154995-0. 631p.
[16] Jean Clair Ngoay-Kossy, Serge Hubert Zébazé Togouet, Solange Patricia Wango, Serge Florent Bolevane Ouantinam, Siméon Tchakonté, et al.. (2018) Bioindicators of lotic aquatic environments in the Central African Republic: benthic macro-invertebrates and anthropogenic pressure of the Nguitto river. Journal of Ecology, Earth and Life, National Society for the Protection of Nature, 73 (4), pp. 603-616. ffhal- 03533290.
[17] Foussard V. and Etcheber H. (2011). Proposal for a strategy for monitoring physico-chemical parameters for the estuaries of the Seine, the Loire and the Gironde; Report CR1 CNRS, Univ. Bordeaux. 71p.
[18] Ghizellaoui, S., & Ghizellaoui, S. (2010). Evaluation of the quality of waters treated by the activated muds station in Oued El Athmania. Desalination, 250 (1), 438–443. https://doi.org/10.1016/j.desal.2009.09.074
[19] Benajib MH, Saoud Y., Lamribah A., Ahrikat M., Amajoud N. and Ouled-Zian O. (2013). Evaluation of the microbial quality of groundwater in Martil, Morocco. Review of Water Sciences 26 (3): 223-233.
[20] Mohammed S., Khalid L. and Lhoussaine L. (2017). Epidemiological profile of uropathogenic extended-spectrum beta-lactamase-producing Enterobacteriaceae Epidemiological profile of uropathogenic enterobacteriaceae producing extended-spectrum beta-lactamases. The Pan African Medical Journal; Flight 28: 29.
[21] Njall C., Adiogo D., Bita A., Ateba N., Sume G, Kollo B., Binam F., Tchoua R. (2013). Bacterial ecology of nosocomial infection in the intensive care unit of Laquintinie hospital in Douala, Cameroon. PAMJ. Vol 14 N°140 10.11604/pamd.
[22] Kapso Tchouankep M., Ajeagah GA, Nkeng Elambo G., Ngassam P. 2018. Bio-characterization of some free-living amoebae in the surface water of the city of Yaoundé: relationship to physico-chemical parameters of the medium. Journal of Applied Biotechnology, 2018, 6 (1): 27-40.
[23] Xi, C., Zhang, Y., Marrs, C., Ye, W., Simon, C., Foxman, B. & Nriagu, J. (2009). Prevalence of antibiotic resistance in drinking water treatment and distribution systems. Appl. About. Microbiol, 75 (17): 5714–5718.
[24] Yoder J, Roberts V, Craun GF, Hill V, Hicks LA, Alexander NT, Radke V, Calderon RL, Hlavsa MC, Beach MJ, Roy SL; (2008). Centers for Disease Control and Prevention (CDC). Surveillance for waterborne disease and outbreaks associated with drinking water and water not intended for drinking--United States, 2005-2006. MMWR Surveill Summ. 2008 Sep 12; 57 (9): 39-62. Erratum in: MMWR Surveill Summ. 2008 Oct 10; 57 (40): 1105. PMID: 18784643.
[25] Health Canada. (2013). Advice on waterborne pathogenic bacteria. Water and Air Quality Bureau, Healthy Environments and Consumer Safety Branch, Health Canada, Ottawa, Ontario. (Catalog No. H129-25/1-2014E-PDF). 61p.
Cite This Article
  • APA Style

    Tonmeu Douyong Chimene Sandrine, Nguepidjo Gilbert, Kapso Tchouankep Mireille, Ewodo Mboudou Guillaume. (2022). Sanitary Status and Bio-monitoring of Surface Water Quality in the City of Maroua (Far North, Cameroon). American Journal of Biomedical and Life Sciences, 10(3), 70-80. https://doi.org/10.11648/j.ajbls.20221003.13

    Copy | Download

    ACS Style

    Tonmeu Douyong Chimene Sandrine; Nguepidjo Gilbert; Kapso Tchouankep Mireille; Ewodo Mboudou Guillaume. Sanitary Status and Bio-monitoring of Surface Water Quality in the City of Maroua (Far North, Cameroon). Am. J. Biomed. Life Sci. 2022, 10(3), 70-80. doi: 10.11648/j.ajbls.20221003.13

    Copy | Download

    AMA Style

    Tonmeu Douyong Chimene Sandrine, Nguepidjo Gilbert, Kapso Tchouankep Mireille, Ewodo Mboudou Guillaume. Sanitary Status and Bio-monitoring of Surface Water Quality in the City of Maroua (Far North, Cameroon). Am J Biomed Life Sci. 2022;10(3):70-80. doi: 10.11648/j.ajbls.20221003.13

    Copy | Download

  • @article{10.11648/j.ajbls.20221003.13,
      author = {Tonmeu Douyong Chimene Sandrine and Nguepidjo Gilbert and Kapso Tchouankep Mireille and Ewodo Mboudou Guillaume},
      title = {Sanitary Status and Bio-monitoring of Surface Water Quality in the City of Maroua (Far North, Cameroon)},
      journal = {American Journal of Biomedical and Life Sciences},
      volume = {10},
      number = {3},
      pages = {70-80},
      doi = {10.11648/j.ajbls.20221003.13},
      url = {https://doi.org/10.11648/j.ajbls.20221003.13},
      eprint = {https://article.sciencepublishinggroup.com/pdf/10.11648.j.ajbls.20221003.13},
      abstract = {A study to assess the physico-chemical and microbiological quality of surface water was conducted from September 2019 to September 2020 in the town of Maroua. With the objective of evaluating the physico-chemical and microbiological quality of the surface water of this town. The sampling stations were chosen on 3 main watercourses in each district of the town. Sampling was done on a fortnightly basis for one year. The results were grouped by seasons. The physico-chemical analyzes consisted of measuring the following parameters: temperature, pH, electrical conductivity, turbidity, chloride, sodium and sulphate content. The biological analyzes of the water focused on the search for bacteria, yeasts and microscopic fungi. The spatiotemporal variations of the physico-chemical parameters revealed water with relatively high temperatures during the two seasons. Suspended solids are generally higher in water during the rainy season (45, 227, 321 and 427 mg/l respectively at M4, M1, M5 and M3) reflecting on high turbidity over 2800 NTU during both seasons at M2 station in Kaliao mayo. The microbiology of water has shown three groups of microorganisms like bacteria, yeasts and fungi. From the microorganisms isolated, the majority were bacteria 84%, yeasts 8% and fungi 8%. The most represented germs in surface water’s samples in Maroua are by medical interest importance: Salmonella spp., Vibrio spp., Legionella spp., then Campylobacter spp. and Aeromonas spp.. Alongside, Mycobacterium species, Candida spp., Cryptococcus spp. and Trichophyton spp. were scarce. These results testify to the occurrence of pathogenic germs in surface water in the city of Maroua. Hence the resurgence of epidemic diseases such as Cholera.},
     year = {2022}
    }
    

    Copy | Download

  • TY  - JOUR
    T1  - Sanitary Status and Bio-monitoring of Surface Water Quality in the City of Maroua (Far North, Cameroon)
    AU  - Tonmeu Douyong Chimene Sandrine
    AU  - Nguepidjo Gilbert
    AU  - Kapso Tchouankep Mireille
    AU  - Ewodo Mboudou Guillaume
    Y1  - 2022/06/09
    PY  - 2022
    N1  - https://doi.org/10.11648/j.ajbls.20221003.13
    DO  - 10.11648/j.ajbls.20221003.13
    T2  - American Journal of Biomedical and Life Sciences
    JF  - American Journal of Biomedical and Life Sciences
    JO  - American Journal of Biomedical and Life Sciences
    SP  - 70
    EP  - 80
    PB  - Science Publishing Group
    SN  - 2330-880X
    UR  - https://doi.org/10.11648/j.ajbls.20221003.13
    AB  - A study to assess the physico-chemical and microbiological quality of surface water was conducted from September 2019 to September 2020 in the town of Maroua. With the objective of evaluating the physico-chemical and microbiological quality of the surface water of this town. The sampling stations were chosen on 3 main watercourses in each district of the town. Sampling was done on a fortnightly basis for one year. The results were grouped by seasons. The physico-chemical analyzes consisted of measuring the following parameters: temperature, pH, electrical conductivity, turbidity, chloride, sodium and sulphate content. The biological analyzes of the water focused on the search for bacteria, yeasts and microscopic fungi. The spatiotemporal variations of the physico-chemical parameters revealed water with relatively high temperatures during the two seasons. Suspended solids are generally higher in water during the rainy season (45, 227, 321 and 427 mg/l respectively at M4, M1, M5 and M3) reflecting on high turbidity over 2800 NTU during both seasons at M2 station in Kaliao mayo. The microbiology of water has shown three groups of microorganisms like bacteria, yeasts and fungi. From the microorganisms isolated, the majority were bacteria 84%, yeasts 8% and fungi 8%. The most represented germs in surface water’s samples in Maroua are by medical interest importance: Salmonella spp., Vibrio spp., Legionella spp., then Campylobacter spp. and Aeromonas spp.. Alongside, Mycobacterium species, Candida spp., Cryptococcus spp. and Trichophyton spp. were scarce. These results testify to the occurrence of pathogenic germs in surface water in the city of Maroua. Hence the resurgence of epidemic diseases such as Cholera.
    VL  - 10
    IS  - 3
    ER  - 

    Copy | Download

Author Information
  • Department of Public Health, Faculty of Health and Life Sciences, Distant Production House University (DPHU), Kigali, Rwanda

  • Department of Public Health, Faculty of Health and Life Sciences, Distant Production House University (DPHU), Kigali, Rwanda

  • Department of Public Health, Faculty of Health and Life Sciences, Distant Production House University (DPHU), Kigali, Rwanda

  • Department of Hydraulics and Water Control (HYMAE) National School, Polytechnic of Maroua, University of Maroua, Maroua, Cameroon

  • Sections