Background: Rat permanent coronary artery ligation is surgical model mimicking coronary artery ischemia and myocardial infarct (MI) injury, both sequels of coronary artery disease (CAD). The aim of this publication is to provide comprehensive, detailed description of rat load-dependent and independent hemodynamic assessment at baseline and at 28 days post-myocardial ischemia and remodeling. Materials and Methods: the detailed depiction of rat-MI model is followed by a thorough assessment of hemodynamics by two-dimensional (2D) echocardiography and invasive pressure-volume (PV) catheterization. Results: Quantification of post-MI using 2D M-mode showed a significant increase in end-systolic and end-diastolic dimensions with a decrease of fractional shortening. PV load-dependent hemodynamics at 28 days showed a rightward shift of PV loop on the volume axis, characterized by an increase of LVEDV; (319±73 vs. 215±79 µl; P<0.001) and the LVESV (157±39 vs. 57±28 µl; P<0.001). Both dpdtmax and ESP were significantly influenced by decreasing the number of myocytes, leading to a significant decrease of dpdtmax (5786±1443 vs. 9609±4126 mmHg; P<0.01) and ESP (91.5±12 vs. 108.2±13 mmHg; P<0.001). Loss of contractile myocytes had an effect on the cardiac output (CO) and ejection fraction (EF); (49±12 vs. 68±3.5 ml/min; P<0.05) and (50±8.5 vs. 76±4.9 % P<0.001). Diastolic dysfunction had a major influence on LV lusitropy at day 28 post-MI characterized by prolonged LV filling at higher LVEDP (9.1±2.9 vs. 5.18±2.5 % P<0.01), higher Tau values, time to peak filling and dpdt min (-4850±1062 vs. 5876±1443 mmHg; P<0.001). Using histopathology, calculated HW/BW ratio (g/mg) (3.1±0.22 vs. 3.82±0.39; P<0.001), reflected hypertrophy of post-remodeled myocardium. Conclusion: Heart failure (HF) post-permanent coronary artery ligation influences both systolic and diastolic hemodynamics. Comprehensive assessment of modeled HF using load-dependent and independent indices enables its clinical translation.

Published in International Journal of Clinical and Experimental Medical Sciences (Volume 2, Issue 3)
DOI 10.11648/j.ijcems.20160203.12
Page(s) 40-51
Creative Commons

This is an Open Access article, distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution and reproduction in any medium or format, provided the original work is properly cited.

Copyright

Copyright © The Author(s), 2024. Published by Science Publishing Group

Keywords

Permanent Coronary Artery Ligation, Rat Model, Echocardiography, Invasive Pressure-Volume Hemodynamics

References
[1] Arbustini E, Dal Bello B, Morbini P, et al. Plaque erosion is a major substrate for coronary thrombosis in acute myocardial infarction. Heart. 1999; 82(3): 269-72.
[2] Heimburger RF. Injection into pericardial sac and ligation of coronary artery of the rat. Arch Surg. 1946; 52: 677-89.
[3] Kaufman N, Gavan TL, Hill RW. Experimental myocardial infarction in the rat. AMA Arch Pathol. 1959; 67(5): 482-8.
[4] Selye H, Bajusz E, Grasso S, et al. Simple techniques for the surgical occlusion of coronary vessels in the rat. Angiology. 1960; 11: 398-407.
[5] Pfeffer MA, Pfeffer JM, Fishbein MC, et al. Myocardial infarct size and ventricular function in rats. Circ Res. 1979; 44(4): 503-12.
[6] Ader R, Chatterjee K, Ports T, et al. Immediate and sustained hemodynamic and clinical improvement in chronic heart failure by an oral angiotensin-converting enzyme inhibitor. Circulation. 1980; 61(5): 931-7.
[7] Packer M, Medina N, Yushak M. Comparative immediate hemodynamic and hormonal effects of amrinone and captopril in patients with severe chronic heart failure. Am J Med Sci. 1986; 291(1): 8-15.
[8] LeJemtel TH, Keung E, Frishman WH, et al. Hemodynamic effects of captopril in patients with severe chronic heart failure. Am J Cardiol. 1982; 49(6): 1484-8.
[9] Chen J, Petrov A, Yaniz-Galende E, et al. The impact of pressure overload on coronary vascular changes following myocardial infarction in rats. Am J Physiol Heart Circ Physiol. 2013; 304(5): 719-28.
[10] Liu YH, Yang XP, Nass O, et al. Chronic heart failure induced by coronary artery ligation in Lewis inbred rats. Am J Physiol. 1997; 272: 722-7.
[11] Pfeffer MA, Pfeffer JM, Steinberg C, et al. Survival after an experimental myocardial infarction: beneficial effects of long-term therapy with captopril. Circulation. 1985; 72(2): 406-12.
[12] Huwer H, Winning J, Vollmar B, et al. Model of chronic systolic and diastolic dysfunction after cryothermia-induced myocardial necrosis in rats. Comp Med. 2000; 50(4): 385-90.
[13] Li RK, Mickle DA, Weisel RD, et al. Optimal time for cardiomyocyte transplantation to maximize myocardial function after left ventricular injury. Ann Thorac Surg. 2001; 72(6): 1957-63.
[14] Costa AR, Panda NC, Yong S, et al. Optical mapping of cryoinjured rat myocardium grafted with mesenchymal stem cells. Am J Physiol Heart Circ Physiol. 2012; 302(1): 270-7.
[15] Jin J, Jeong SI, Shin YM, et al. Transplantation of mesenchymal stem cells within a poly(lactide-co-epsilon-caprolactone) scaffold improves cardiac function in a rat myocardial infarction model. Eur J Heart Fail. 2009; 11(2): 147-53.
[16] Opitz CF, Mitchell GF, Pfeffer MA, et al. Arrhythmias and death after coronary artery occlusion in the rat. Continuous telemetric ECG monitoring in conscious, untethered rats. Circulation. 1995; 92(2): 253-61.
[17] Konecny F, Zou J, Husain M, et al. Post-myocardial infarct p27 fusion protein intravenous delivery averts adverse remodelling and improves heart function and survival in rodents. Cardiovasc Res. 2012; 94(3): 492-500.
[18] McPherson R, Pertsemlidis A, Kavaslar N, et al. A common allele on chromosome 9 associated with coronary heart disease. Science. 2007; 316: 1488-91.
[19] Helgadottir A, Thorleifsson G, Manolescu A, et al. A common variant on chromosome 9p21 affects the risk of myocardial infarction. Science. 2007; 316: 1491-3.
[20] Klocke R, Tian W, Kuhlmann MT, et al. Surgical animal models of heart failure related to coronary heart disease. Cardiovasc Res. 2007; 74(1): 29-38.
[21] Lang RM, Badano LP, Mor-Avi V, et al. Recommendations for cardiac chamber quantification by echocardiography in adults: an update from the American Society of Echocardiography and the European Association of Cardiovascular Imaging. J Am Soc Echocardiogr. 2015; 28(1): 1-39.e14.
[22] Brown L, Fenning A, Chan V, et al. Echocardiographic assessment of cardiac structure and function in rats. Heart Lung Circ. 2002; 11(3): 167-73.
[23] Lewis JF, Kuo LC, Nelson JG, et al. Pulsed Doppler echocardiographic determination of stroke volume and cardiac output: clinical validation of two new methods using the apical window. Circulation. 1984; 70(3): 425-31
[24] Quiñones MA, Otto CM, Stoddard M, et al. Doppler Quantification Task Force of the Nomenclature and Standards Committee of the American Society of Echocardiography. Recommendations for quantification of Doppler echocardiography: a report from the Doppler Quantification Task Force of the Nomenclature and Standards Committee of the American Society of Echocardiography. J Am Soc Echocardiogr. 2002; 15(2): 167-84.
[25] Setzen G, Williams EF. Tissue response to suture materials implanted subcutaneously in a rabbit model. Plast Reconstr Surg. 1997; 100: 1788–95.
[26] Koh SG, Brenner DA, Korzick DH, et al. Exercise intolerance during post-MI heart failure in rats: prevention with supplemental dietary propionyl-L-carnitine. Cardiovasc Drugs Ther. 2003; 17(1): 7-14.
[27] Zornoff LA, Paiva SA, Minicucci MF, et al. Experimental myocardium infarction in rats: analysis of the model. Arq Bras Cardiol. 2009; 93(4): 434-440.
[28] Fletcher PJ, Pfeffer JM, Pfeffer MA, et al. Left ventricular diastolic pressure-volume relations in rats with healed myocardial infarction. Effects on systolic function. Circ Res. 1981; 49(3): 618-26.
[29] Blaudszun G, Morel DR. Relevance of the volume-axis intercept, V0, compared with the slope of end-systolic pressure-volume relationship in response to large variations in inotropy and afterload in rats. Exp Physiol. 2011; 96(11): 1179-95.
[30] Takada K, Sumikawa K, Kamibayashi T, et al. Comparative efficacy of antiarrhythmic agents in preventing halothane-epinephrine arrhythmias in rats. Anesthesiology. 1993; 79(3): 563-70.
[31] Morvay N, Baczkó I, Sztojkov-Ivanov A, et al. Long-term pretreatment with desethylamiodarone (DEA) or amiodarone (AMIO) protects against coronary artery occlusion induced ventricular arrhythmias in conscious rats. Can J Physiol Pharmacol. 2015; 93(9): 773-7.
[32] Pasipoularides A. Right and left ventricular diastolic flow field: why are measured intraventricular pressure gradients small? Rev Esp Cardiol (Engl Ed). 2013; 66(5): 337-41.
[33] Komajda M, Lam CS. Heart failure with preserved ejection fraction: a clinical dilemma. Eur Heart J. 2014; 35(16): 1022-32.
Cite This Article
  • APA Style

    Filip Konecny. (2016). Assessment of Experimental Permanent Coronary Artery Ligation Using Echocardiography and Invasive Real-Time Pressure-Volume (PV): A Practical Tips to Evaluate Rat Hemodynamics. International Journal of Clinical and Experimental Medical Sciences, 2(3), 40-51. https://doi.org/10.11648/j.ijcems.20160203.12

    Copy | Download

    ACS Style

    Filip Konecny. Assessment of Experimental Permanent Coronary Artery Ligation Using Echocardiography and Invasive Real-Time Pressure-Volume (PV): A Practical Tips to Evaluate Rat Hemodynamics. Int. J. Clin. Exp. Med. Sci. 2016, 2(3), 40-51. doi: 10.11648/j.ijcems.20160203.12

    Copy | Download

    AMA Style

    Filip Konecny. Assessment of Experimental Permanent Coronary Artery Ligation Using Echocardiography and Invasive Real-Time Pressure-Volume (PV): A Practical Tips to Evaluate Rat Hemodynamics. Int J Clin Exp Med Sci. 2016;2(3):40-51. doi: 10.11648/j.ijcems.20160203.12

    Copy | Download

  • @article{10.11648/j.ijcems.20160203.12,
      author = {Filip Konecny},
      title = {Assessment of Experimental Permanent Coronary Artery Ligation Using Echocardiography and Invasive Real-Time Pressure-Volume (PV): A Practical Tips to Evaluate Rat Hemodynamics},
      journal = {International Journal of Clinical and Experimental Medical Sciences},
      volume = {2},
      number = {3},
      pages = {40-51},
      doi = {10.11648/j.ijcems.20160203.12},
      url = {https://doi.org/10.11648/j.ijcems.20160203.12},
      eprint = {https://article.sciencepublishinggroup.com/pdf/10.11648.j.ijcems.20160203.12},
      abstract = {Background: Rat permanent coronary artery ligation is surgical model mimicking coronary artery ischemia and myocardial infarct (MI) injury, both sequels of coronary artery disease (CAD). The aim of this publication is to provide comprehensive, detailed description of rat load-dependent and independent hemodynamic assessment at baseline and at 28 days post-myocardial ischemia and remodeling. Materials and Methods: the detailed depiction of rat-MI model is followed by a thorough assessment of hemodynamics by two-dimensional (2D) echocardiography and invasive pressure-volume (PV) catheterization. Results: Quantification of post-MI using 2D M-mode showed a significant increase in end-systolic and end-diastolic dimensions with a decrease of fractional shortening. PV load-dependent hemodynamics at 28 days showed a rightward shift of PV loop on the volume axis, characterized by an increase of LVEDV; (319±73 vs. 215±79 µl; P<0.001) and the LVESV (157±39 vs. 57±28 µl; P<0.001). Both dpdtmax and ESP were significantly influenced by decreasing the number of myocytes, leading to a significant decrease of dpdtmax (5786±1443 vs. 9609±4126 mmHg; P<0.01) and ESP (91.5±12 vs. 108.2±13 mmHg; P<0.001). Loss of contractile myocytes had an effect on the cardiac output (CO) and ejection fraction (EF); (49±12 vs. 68±3.5 ml/min; P<0.05) and (50±8.5 vs. 76±4.9 % P<0.001). Diastolic dysfunction had a major influence on LV lusitropy at day 28 post-MI characterized by prolonged LV filling at higher LVEDP (9.1±2.9 vs. 5.18±2.5 % P<0.01), higher Tau values, time to peak filling and dpdt min (-4850±1062 vs. 5876±1443 mmHg; P<0.001). Using histopathology, calculated HW/BW ratio (g/mg) (3.1±0.22 vs. 3.82±0.39; P<0.001), reflected hypertrophy of post-remodeled myocardium. Conclusion: Heart failure (HF) post-permanent coronary artery ligation influences both systolic and diastolic hemodynamics. Comprehensive assessment of modeled HF using load-dependent and independent indices enables its clinical translation.},
     year = {2016}
    }
    

    Copy | Download

  • TY  - JOUR
    T1  - Assessment of Experimental Permanent Coronary Artery Ligation Using Echocardiography and Invasive Real-Time Pressure-Volume (PV): A Practical Tips to Evaluate Rat Hemodynamics
    AU  - Filip Konecny
    Y1  - 2016/06/20
    PY  - 2016
    N1  - https://doi.org/10.11648/j.ijcems.20160203.12
    DO  - 10.11648/j.ijcems.20160203.12
    T2  - International Journal of Clinical and Experimental Medical Sciences
    JF  - International Journal of Clinical and Experimental Medical Sciences
    JO  - International Journal of Clinical and Experimental Medical Sciences
    SP  - 40
    EP  - 51
    PB  - Science Publishing Group
    SN  - 2469-8032
    UR  - https://doi.org/10.11648/j.ijcems.20160203.12
    AB  - Background: Rat permanent coronary artery ligation is surgical model mimicking coronary artery ischemia and myocardial infarct (MI) injury, both sequels of coronary artery disease (CAD). The aim of this publication is to provide comprehensive, detailed description of rat load-dependent and independent hemodynamic assessment at baseline and at 28 days post-myocardial ischemia and remodeling. Materials and Methods: the detailed depiction of rat-MI model is followed by a thorough assessment of hemodynamics by two-dimensional (2D) echocardiography and invasive pressure-volume (PV) catheterization. Results: Quantification of post-MI using 2D M-mode showed a significant increase in end-systolic and end-diastolic dimensions with a decrease of fractional shortening. PV load-dependent hemodynamics at 28 days showed a rightward shift of PV loop on the volume axis, characterized by an increase of LVEDV; (319±73 vs. 215±79 µl; P<0.001) and the LVESV (157±39 vs. 57±28 µl; P<0.001). Both dpdtmax and ESP were significantly influenced by decreasing the number of myocytes, leading to a significant decrease of dpdtmax (5786±1443 vs. 9609±4126 mmHg; P<0.01) and ESP (91.5±12 vs. 108.2±13 mmHg; P<0.001). Loss of contractile myocytes had an effect on the cardiac output (CO) and ejection fraction (EF); (49±12 vs. 68±3.5 ml/min; P<0.05) and (50±8.5 vs. 76±4.9 % P<0.001). Diastolic dysfunction had a major influence on LV lusitropy at day 28 post-MI characterized by prolonged LV filling at higher LVEDP (9.1±2.9 vs. 5.18±2.5 % P<0.01), higher Tau values, time to peak filling and dpdt min (-4850±1062 vs. 5876±1443 mmHg; P<0.001). Using histopathology, calculated HW/BW ratio (g/mg) (3.1±0.22 vs. 3.82±0.39; P<0.001), reflected hypertrophy of post-remodeled myocardium. Conclusion: Heart failure (HF) post-permanent coronary artery ligation influences both systolic and diastolic hemodynamics. Comprehensive assessment of modeled HF using load-dependent and independent indices enables its clinical translation.
    VL  - 2
    IS  - 3
    ER  - 

    Copy | Download

Author Information
  • Department of Surgery, Division of Plastic Surgery, Microsurgery, McMaster University, Hamilton, Ontario, Canada

  • Sections