International Journal of Pharmacy and Chemistry

| Peer-Reviewed |

Simultaneous Determination of V (V) and Co (II) as (S)-5-Methoxy-2-[[(4-Methoxy-3, 5-Dimethyl-2-Pyridinyle-Methyle] Sulfinyle]-1H-Benzimidazole Using Derivative Spectrophotometry

Received: 09 June 2015    Accepted: 07 July 2015    Published: 08 July 2015
Views:       Downloads:

Share This Article

Abstract

The reagent (S)-5-methoxy-2-[[(4-methoxy-3, 5-dimethyl-2-pyridinyle-methyle] sulfinyle]-1H-benzimidazole gives greenish yellow coloration with V (V) as well as Co (II) in basic medium. This observation is used for the simultaneous determination of both the metal ions using Zero and second order derivative spectrophotometry. Optimum conditions were established for this determination. Job’s and mole-ratio methods are used for the determination of composition of the metal complexes. Determination of the metal ions was carried out in BAS alloys, and NTP ball bearings.

DOI 10.11648/j.ijpc.20150101.11
Published in International Journal of Pharmacy and Chemistry (Volume 1, Issue 1, July 2015)
Page(s) 1-6
Creative Commons

This is an Open Access article, distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution and reproduction in any medium or format, provided the original work is properly cited.

Copyright

Copyright © The Author(s), 2024. Published by Science Publishing Group

Previous article
Keywords

Vanadium, Cobalt, ESMPZL, Derivative Spectrophotometry, Alloys, Steels and Synthetic Mixtures

References
[1] Deaintith, J. Oxford Dictionary of Chemistry; Oxford University Press: Oxford, 1996; p 123.
[2] Filik H., Yanaz Z., A Sensitive Method for Determining Total Vanadium in Water Samples Using Colorimetric Solid Phase Extraction Fiber Optic Reflectance Spectroscopy, J. Hazard. Mater.,172, p. 1297 (2009).
[3] Filik H., Yanaz Z., Apak R., Selective Determination of Total Vanadium in Water Samples by Cloud Point Extraction of Its Ternary Complex, Anal. Chim.Acta, 620, p. 27 (2008).
[4] Bagherian G., Arab Chamjangali M., EskandariH.,Simultaneous Determination of Cobalt and Palladium in Micellar Media Using H-Point Standard Addition Method and Partial Least Square Regression, Spectrochim. Acta Part A, 67, p. 378 (2007).
[5] Abdollahi H., Zolgharnein J., AzimiG.H., JafarifarD., Simultaneous Spectrophotometric Determinationof Iron and Vanadium by H-Point Standard Addition Method and Partial Least Squares Regression inMicellar Medium, Talanta, 59, p. 1141 (2003).
[6] Verdu-Andres J., Bosch-Reig F., Campins-Falco P., H-point Standard Additions Methods forAnalyteDetermination in Ternary Mixtures, Analyst, 113, p. 1011 (1988).
[7] Afkhami A., Abbasi-Tarighat M., Bahram M., Abdollahi H., A New Strategy for Solving Matrix Effect in Multivariate Calibration Standard Addition Data Using Combination of H- Point Curve Isolation and H-Point Standard Addition Methods, Anal. Chim.Acta, 613, p. 144 (2008).
[8] Pouretedal H.R., Asefi M., H-point Standard Addition Method for Simultaneous Determination of Cobalt(II) and Zinc(II) Ions, J. Iran. Chem. Soc., 4, p. 503 (2007).
[9] Bosch-Reig F., Verdú-Andrés J., Campins-Falcó P.,MolinsLegua C., Study of the Behavior of theAbsorbent Blanks in Analytical Procedures by Using the H-Point Standard Addition Method (HPSAM),Talanta, 41, p. 39 (1994).
[10] Abdollahi H., Simultaneous Spectrophotometric Determination of Chromium (VI) and Iron (III) withChromogenic Mixed Reagents by H-Point Standard Addition Method and Partial Least Squares Regression, Anal. Chim. Acta, 442, p. 327 (2001).
[11] Afkhami A., ZareiA.R., Simultaneous Spectrophotometric Determination of Hydrazine and Pphenylhydrazine Media Using H-Point Standard Addition Method, Talanta, 62, p. 559 (2004).
[12] Campins-Falcó P., Verdú-Andrés J., Bosch-Reig F., Development of the H-Point Standard AdditionsMethod for the Use of Spectrofluorimetry and Synchronous Spectrofluorimetry, Analyst 119, p. 2123 (1994).
[13] Safavi A., Abdollahi H., Sedaghatpour F., Zeinali S., Kinetic Spectrophotometric Determination of V(IV) in the Presence of V(V) by the H-Point Standard Addition Method, Anal.Chim.Acta, 409, p. 275 (2000).
[14] Safavi A., Tohidi M., Simultaneous Kinetic Determination of Levodopa and Carbidopa by H-Point Standard Addition Method. J. Pharm. Biomed. Anal., 44, p. 313 (2007).
[15] Blasco-Gomez F., Campins-Falcó P., Bosch-Reig F., Molins-Legua C., Herráez-Hernández R., H-Point Curve Isolation Method for Coupled Liquid Chromatography and UV-Vis Spectrophotometry, Anal.Chem., 72, p. 2559 (2000).
[16] Campins-Falco P., Verdu-Andres J., Bosch-Reig F., MolinsLegua C., Generalized H-Point StandardAdditions Method for Analyte Determination in Unknown Samples, Anal.Chim. Acta, 302, p. 323 (1995).
[17] Campins-Falco P., Blasco-Gomez F., Bosch-Reig F., The H-Point and Generalized H-Point StandardAdditions Methods for Flow Injection Procedures, Talanta, 47, p. 193 (1998).
[18] Verdu-Andres J., Bosch-Reig F., Campins-Falco P., Analyte Estimation Using the Generalized H-Point Standard Additions Method and a New Methodology for Locating Linear Spectral Intervals for Unknown Interferents, J. Chemom., 12, p. 27 (1998).
[19] Blasco-Gomez F., Campins-Falco P., Molins-Llegua C., Herraez-hernandez R., H-Point CurveIsolation Method for Coupled Liquid Chromatography and UV-Visible Spectrophotometry, Anal. Chem. 72, p. 2559 (2000).
[20] S.N.Lanjwani and A.K.Chamer , Journal of Chromatographic, 1996, Vol-43, Issue 7- 8,431-432.
[21] T.Kiriyama and R.Kuroda Analyst Issue 1274, 1982, 505-510.
[22] Bing Chan and SandanobuInoue,Jouranal of Chromatographic Science, Vol 37, 1999.
[23] A. Praveen Kumar and V.Krishna Reddy, Journal of main group channel, ISSN, 1024-1221, 1745-1167, 2006.
Author Information
  • Department of Chemistry, Sri Krishnadevaraya University, Anantapur, India

  • Department of Chemistry, Sri Krishnadevaraya University, Anantapur, India

  • Department of Chemistry, NEC College, Narasaraopet, Guntur, Andhra Pradesh, India

Cite This Article
  • APA Style

    B. Ranganath, P. Venkataramana, M. R. Jayapal. (2015). Simultaneous Determination of V (V) and Co (II) as (S)-5-Methoxy-2-[[(4-Methoxy-3, 5-Dimethyl-2-Pyridinyle-Methyle] Sulfinyle]-1H-Benzimidazole Using Derivative Spectrophotometry. International Journal of Pharmacy and Chemistry, 1(1), 1-6. https://doi.org/10.11648/j.ijpc.20150101.11

    Copy | Download

    ACS Style

    B. Ranganath; P. Venkataramana; M. R. Jayapal. Simultaneous Determination of V (V) and Co (II) as (S)-5-Methoxy-2-[[(4-Methoxy-3, 5-Dimethyl-2-Pyridinyle-Methyle] Sulfinyle]-1H-Benzimidazole Using Derivative Spectrophotometry. Int. J. Pharm. Chem. 2015, 1(1), 1-6. doi: 10.11648/j.ijpc.20150101.11

    Copy | Download

    AMA Style

    B. Ranganath, P. Venkataramana, M. R. Jayapal. Simultaneous Determination of V (V) and Co (II) as (S)-5-Methoxy-2-[[(4-Methoxy-3, 5-Dimethyl-2-Pyridinyle-Methyle] Sulfinyle]-1H-Benzimidazole Using Derivative Spectrophotometry. Int J Pharm Chem. 2015;1(1):1-6. doi: 10.11648/j.ijpc.20150101.11

    Copy | Download

  • @article{10.11648/j.ijpc.20150101.11,
      author = {B. Ranganath and P. Venkataramana and M. R. Jayapal},
      title = {Simultaneous Determination of V (V) and Co (II) as (S)-5-Methoxy-2-[[(4-Methoxy-3, 5-Dimethyl-2-Pyridinyle-Methyle] Sulfinyle]-1H-Benzimidazole Using Derivative Spectrophotometry},
      journal = {International Journal of Pharmacy and Chemistry},
      volume = {1},
      number = {1},
      pages = {1-6},
      doi = {10.11648/j.ijpc.20150101.11},
      url = {https://doi.org/10.11648/j.ijpc.20150101.11},
      eprint = {https://download.sciencepg.com/pdf/10.11648.j.ijpc.20150101.11},
      abstract = {The reagent (S)-5-methoxy-2-[[(4-methoxy-3, 5-dimethyl-2-pyridinyle-methyle] sulfinyle]-1H-benzimidazole gives greenish yellow coloration with V (V) as well as Co (II) in basic medium. This observation is used for the simultaneous determination of both the metal ions using Zero and second order derivative spectrophotometry. Optimum conditions were established for this determination. Job’s and mole-ratio methods are used for the determination of composition of the metal complexes. Determination of the metal ions was carried out in BAS alloys, and NTP ball bearings.},
     year = {2015}
    }
    

    Copy | Download

  • TY  - JOUR
    T1  - Simultaneous Determination of V (V) and Co (II) as (S)-5-Methoxy-2-[[(4-Methoxy-3, 5-Dimethyl-2-Pyridinyle-Methyle] Sulfinyle]-1H-Benzimidazole Using Derivative Spectrophotometry
    AU  - B. Ranganath
    AU  - P. Venkataramana
    AU  - M. R. Jayapal
    Y1  - 2015/07/08
    PY  - 2015
    N1  - https://doi.org/10.11648/j.ijpc.20150101.11
    DO  - 10.11648/j.ijpc.20150101.11
    T2  - International Journal of Pharmacy and Chemistry
    JF  - International Journal of Pharmacy and Chemistry
    JO  - International Journal of Pharmacy and Chemistry
    SP  - 1
    EP  - 6
    PB  - Science Publishing Group
    SN  - 2575-5749
    UR  - https://doi.org/10.11648/j.ijpc.20150101.11
    AB  - The reagent (S)-5-methoxy-2-[[(4-methoxy-3, 5-dimethyl-2-pyridinyle-methyle] sulfinyle]-1H-benzimidazole gives greenish yellow coloration with V (V) as well as Co (II) in basic medium. This observation is used for the simultaneous determination of both the metal ions using Zero and second order derivative spectrophotometry. Optimum conditions were established for this determination. Job’s and mole-ratio methods are used for the determination of composition of the metal complexes. Determination of the metal ions was carried out in BAS alloys, and NTP ball bearings.
    VL  - 1
    IS  - 1
    ER  - 

    Copy | Download

  • Sections