The thermal comfort of a riverside residential settlement differs from a non-riverside residential one, which might be caused by a microclimatic difference. Inducing wind from a river to cross the whole riverside residential settlement could improve the outdoor thermal comfort significantly. Such knowledge triggers a study of utilizing river wind to enhance thermal comfort to a riverside residential settlement in southern China. The study explores various possible layouts of a riverside residential settlement using Computational Fluid Dynamic (CFD) simulations. The thermal comfort index OUT_SET* (the Standard Effective Temperature) that combines effects of air temperature, radiation, wind velocity, and the water evaporation, has been used to evaluate thermal comfort of various riverside residential settlements due to different design layouts. The result showed that the loose enclosed layout is the best one for the thermal comfort whereas the back and front aligned determinant layout is the worst. In order to apply the results into a real world, a case study has been made to the Shenzhen Nan Hua Cun. The thermal environment of this Chinese southern riverside residential settlement has been researched. According to thermal problems revealed by CFD simulation, an optimization design layout was proposed by applying the study results. Eventually, the thermal comfort between the current situation and the optimization design has been compared.

DOI 10.11648/j.larp.20190404.14
Published in Landscape Architecture and Regional Planning (Volume 4, Issue 4, December 2019)
Page(s) 87-95
Creative Commons

This is an Open Access article, distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution and reproduction in any medium or format, provided the original work is properly cited.

Copyright

Copyright © The Author(s), 2024. Published by Science Publishing Group

Keywords

Design Layout, Outdoor Space, Thermal Comfort, Riverside Residential Settlement

References
[1] Liu, W. W., Y. X. Zhang and Q. H. Deng (2016). The effects of urban microclimate on outdoor thermal sensation and neutral temperature in hot-summer and cold-winter climate. Energy and Buildings 128, 190-197.
[2] Wang, Y. S., Q. M. Zhan and W. L. Ouyang (2019). How to quantify the relationship between spatial distribution of urban waterbodies and land surface temperature. Science of the Total Environment 671, 1-9.
[3] Keery, J., A. Binley, N. Crook and J. W. N. Smith (2007). Temporal and spatial variability of groundwater–surface water fluxes: Development and application of ·an analytical method using temperature time series. Journal of Hydrology 336, 1-16.
[4] Theeuwes, N. E., A. Solcerová and G. J. Steeneveld (2013). Modelling the influence of open water surfaces on the summertime temperature and thermal comfort in the city. J. Geophysical Research: Atmospheres 118, 8881-8896.
[5] Lin, H., J. Q. Niu, H. Q. Ma and Y. Fan (2017). Urban water body reduction of heat island effects – A case study of Nanjng City. J. Xinyang Normal University, Natural Science Edition 30 (2), 234–238.
[6] Hathway, E. A., S. Sharples (2012). The interaction of river and urban form in mitigating in the Urban Heat Island effect: A UK case study. Building and Environment 58, 14-22.
[7] Song, X. C., J. Liu and L. Yu (2016). Pedestrian environment prediction with different types of on-shore building distribution. Journal of Central South University 23, 955-968.
[8] Gaitani, N., G. Mihalakakou and M. Santamouris (2007). On the use of bioclimatic architecture principles in order to improve thermal comfort conditions in outdoor spaces. Building and Environment 42 (1), 317-324.
[9] Martínez-Arroyo, A. and E. Jáuregui (2000). On the environmental role of urban lakes in Mexico City. Urban Ecosystems 4, 145–166.
[10] Nikolopoulou, M., N. Baker and K. Steemers (2001). Thermal comfort in outdoor urban spaces: understanding the human parameter. Solar Energy 70 (3), 227–235.
[11] ASHRAE. Handbook of Fundamentals: Physiological Principles, Comfort, Health. America Society of Heating, Refrigeration and Air-Conditioning Engineers, New York 1997.
[12] Ruiz, M. A., and E. N. Correa (2015). Adaptive model for outdoor thermal comfort assessment in an Oasis city of arid climate. Building and Environment 85, 40-51.
[13] Chen, L., and E. Ng (2012). Outdoor thermal comfort and outdoor activities: A review of research in the past decade. Cities 29 (2), 118-125.
[14] Ahmed, K. S. (2003). Comfort in urban spaces: defining the boundaries of outdoor thermal comfort for the tropical urban environments. Energy and Buildings 35 (1), 103-110.
[15] Yang, W., N. H Wong and S. K. Jusuf (2013). Thermal comfort in outdoor urban spaces in Singapore. Building and Environment 59 (3), 426-435.
[16] Makaremi, N., E. Salleh, M. Z. Jaafar, et al. (2012). Thermal comfort conditions of shaded outdoor spaces in hot and humid climate of Malaysia. Building and Environment 48 (1), 7-14.
[17] Lin, B., X. F Li, Y. X. Zhu, et al. (2008). Numerical simulation studies of the different vegetation patterns’ effects on outdoor pedestrian thermal comfort. Journal of Wind Engineering and Industrial Aerodynamics 96 (10-11), 1707-1718.
[18] Xi, T., Q. Li and A. Mochida (2012). Study on the outdoor thermal environment and thermal comfort around campus clusters in subtropical urban areas. Building and Environment 52 (6), 162-170.
[19] Spagnolo, J., and R. D. Dear (2003). A field study of thermal comfort in outdoor and semi-outdoor environments in subtropical Sydney Australia. Building and Environment 32, 721-738.
[20] Cohen, P., O. Potchter and A. Matzarakis (2013). Human thermal perception of Coastal Mediterranean outdoor urban environments. Applied Geography 37, 1-10.
[21] E. Ng, Designing high-density cities for social and environmental sustainability. Earthscan, London: Sterling, VA, 2009.
[22] Kántor, N., and J. Unger (2010). Benefits and opportunities of adopting GIS in thermal comfort studies in resting places: An urban park as an example. Landscape and Urban Planning 98 (1), 36–46.
[23] Hwang, R. L., T. P. Lin and A. Matzarakis (2011). Seasonal effects of urban street shading on long-term outdoor thermal comfort. Building and Environment 46 (4), 863-870.
[24] Lin, T. P. (2009). Thermal perception, adaptation and attendance in a public square in hot and humid regions. Building and Environment 44, 2017–2026.
Author Information
  • School of Architecture, Harbin Institute of Technology, Shenzhen, China; Shenzhen Key Laboratory of Urban Planning and Decision-Making, Shenzhen, China; Shanghai Key Laboratory of Urban Renewal and Spatial Optimization Technology, Shanghai, China

  • Shenzhen Key Laboratory of Urban Planning and Decision-Making, Shenzhen, China; School of Architecture, Harbin Institute of Technology, Harbin, China

  • School of Architecture, Harbin Institute of Technology, Shenzhen, China; Shenzhen Key Laboratory of Urban Planning and Decision-Making, Shenzhen, China; Shanghai Key Laboratory of Urban Renewal and Spatial Optimization Technology, Shanghai, China

Cite This Article
  • APA Style

    Lei Yu, Jing Liu, Jingwen Tao. (2019). Optimizing Design Layout of a Riverside Residential Settlement in terms of the Thermal Comfort. Landscape Architecture and Regional Planning, 4(4), 87-95. https://doi.org/10.11648/j.larp.20190404.14

    Copy | Download

    ACS Style

    Lei Yu; Jing Liu; Jingwen Tao. Optimizing Design Layout of a Riverside Residential Settlement in terms of the Thermal Comfort. Landsc. Archit. Reg. Plan. 2019, 4(4), 87-95. doi: 10.11648/j.larp.20190404.14

    Copy | Download

    AMA Style

    Lei Yu, Jing Liu, Jingwen Tao. Optimizing Design Layout of a Riverside Residential Settlement in terms of the Thermal Comfort. Landsc Archit Reg Plan. 2019;4(4):87-95. doi: 10.11648/j.larp.20190404.14

    Copy | Download

  • @article{10.11648/j.larp.20190404.14,
      author = {Lei Yu and Jing Liu and Jingwen Tao},
      title = {Optimizing Design Layout of a Riverside Residential Settlement in terms of the Thermal Comfort},
      journal = {Landscape Architecture and Regional Planning},
      volume = {4},
      number = {4},
      pages = {87-95},
      doi = {10.11648/j.larp.20190404.14},
      url = {https://doi.org/10.11648/j.larp.20190404.14},
      eprint = {https://download.sciencepg.com/pdf/10.11648.j.larp.20190404.14},
      abstract = {The thermal comfort of a riverside residential settlement differs from a non-riverside residential one, which might be caused by a microclimatic difference. Inducing wind from a river to cross the whole riverside residential settlement could improve the outdoor thermal comfort significantly. Such knowledge triggers a study of utilizing river wind to enhance thermal comfort to a riverside residential settlement in southern China. The study explores various possible layouts of a riverside residential settlement using Computational Fluid Dynamic (CFD) simulations. The thermal comfort index OUT_SET* (the Standard Effective Temperature) that combines effects of air temperature, radiation, wind velocity, and the water evaporation, has been used to evaluate thermal comfort of various riverside residential settlements due to different design layouts. The result showed that the loose enclosed layout is the best one for the thermal comfort whereas the back and front aligned determinant layout is the worst. In order to apply the results into a real world, a case study has been made to the Shenzhen Nan Hua Cun. The thermal environment of this Chinese southern riverside residential settlement has been researched. According to thermal problems revealed by CFD simulation, an optimization design layout was proposed by applying the study results. Eventually, the thermal comfort between the current situation and the optimization design has been compared.},
     year = {2019}
    }
    

    Copy | Download

  • TY  - JOUR
    T1  - Optimizing Design Layout of a Riverside Residential Settlement in terms of the Thermal Comfort
    AU  - Lei Yu
    AU  - Jing Liu
    AU  - Jingwen Tao
    Y1  - 2019/12/30
    PY  - 2019
    N1  - https://doi.org/10.11648/j.larp.20190404.14
    DO  - 10.11648/j.larp.20190404.14
    T2  - Landscape Architecture and Regional Planning
    JF  - Landscape Architecture and Regional Planning
    JO  - Landscape Architecture and Regional Planning
    SP  - 87
    EP  - 95
    PB  - Science Publishing Group
    SN  - 2637-4374
    UR  - https://doi.org/10.11648/j.larp.20190404.14
    AB  - The thermal comfort of a riverside residential settlement differs from a non-riverside residential one, which might be caused by a microclimatic difference. Inducing wind from a river to cross the whole riverside residential settlement could improve the outdoor thermal comfort significantly. Such knowledge triggers a study of utilizing river wind to enhance thermal comfort to a riverside residential settlement in southern China. The study explores various possible layouts of a riverside residential settlement using Computational Fluid Dynamic (CFD) simulations. The thermal comfort index OUT_SET* (the Standard Effective Temperature) that combines effects of air temperature, radiation, wind velocity, and the water evaporation, has been used to evaluate thermal comfort of various riverside residential settlements due to different design layouts. The result showed that the loose enclosed layout is the best one for the thermal comfort whereas the back and front aligned determinant layout is the worst. In order to apply the results into a real world, a case study has been made to the Shenzhen Nan Hua Cun. The thermal environment of this Chinese southern riverside residential settlement has been researched. According to thermal problems revealed by CFD simulation, an optimization design layout was proposed by applying the study results. Eventually, the thermal comfort between the current situation and the optimization design has been compared.